Procurement of Laboratory Equipment under HEC NRPU Project

Benchtop Laboratory Freeze
Dryer with multi-manifold Condensing Capacity: up to 4 kg Condensing temperature: up to -60°C
Freeze drying area: upto 0.18 m2 Condensing performance: 4kg/24 h Along with vacuum pump with
pumping rate 2L per second or better. Vacuum pump with anti-oil return and smoke filter. One year warranty or better.

Microtome (Rotary Type)
Section Thickness Range: 0.5 μm to 60 μm (in 0.5 μm increments from 0.5 μm to 2 μm, and larger increments at higher ranges). Trimming Function: Coarse trimming thickness ranging from 10
μm to 60 μm.
Specimen Orientation: Horizontal ± 8°, Vertical ± 8°.
Horizontal Specimen Feed: Approx. 28 mm.
Vertical Specimen Stroke: Approx.
60 mm.
Blade System: Compatible with both high-profile and low-profile
disposable blades.
Safety: Must feature a quick-lock mechanism on the handwheel and a blade guard for user protection.
Disposable Microtome Blades: Low-profile and high-profile
dispensers.
Tissue Floating Bath: Digital, thermostatically controlled water bath.
Slide Drying Warmer: Electric hot plate or slide dryer.

Olympus Microscope with Camera
10x paired eyepieces (Field Number 20)
Trinocular system (Anti-fungal treated), infinity optics, 4×–
100× objectives, ≥5 MP CMOS camera, USB/HDMI, imaging software, Mechanical stage with
specimen holder, Abbe Condenser NA 1.25 High-intensity LED or Halogen with built-in rechargeable
battery 

Franz Diffusion Cell System
20 cells, diffusion area 1–2 cm², receptor volume 15–20 mL, 32 ± 0.5°C,
magnetic stirring, borosilicate glass system
Orifice manual sampling port: 20 mm Requires pinch clamp
Water bath: 24 inches x 24 inches Temperature adjustment and its probe Stirring speed controller and its probe

PDMS Microneedle Molds
Silicone Template
Material: PDMS Patch Size (D): 8mm x 8mm
Array Size: 10 x 10
Needle Height (A): 300 μm
Needle Base (B): 100 μm
Needle Pitch (C): 500 μm
Length of last microneedle cavity to the edge of the patch (F) can be calculated using the
following formula: F = (patch size - [(n-1) x pitch)] / 2 where n = number of microneedles in one array
Sterilization: Autoclave (optional)
No. of use: repeated use if clean and stored properly

Summery

Published On: 1 day ago

Category(s): Lab Equipment Tenders,

Close Date: 31 August 2026

Status: Active

Company Detail

University of Central Punjab Tenders Published Tender in Newspaper Dunya.

Get all the latest Tender and Auction Notices
across multple Newspapers/Sources of Pakistan.