Plain Cement Concrete including placing, compacting, finishing & curing (Ratio 1:2:4)

Plain Cement Concrete including placing, compacting, finishing & curing (Ratio 1:4:8)

1.375" thick mosaic flooring, including rubbing and polishing complete: Using grey cement

Painting old surfaces: Doors/windows any type First coat

Painting old surfaces: Doors/windows any type Each subsequent coat

Cement plaster 3/8" thick under soffit of RCC roof slabs only upto 20' height: (1:2)

Fabrication of heavy steel work with angle, tees, sheet iron etc for making trusses, girders etc

Erection and removal of Form work with Wood Surface Finshing for RCC or Plain cement Concrete in any shape -Position/Horizontal

Provide & lay topping of concrete 1:2:4, including surface finishing & dividing in panels: 1" thick

Cement plaster 1:4 upto 20' height 1/2" thick

Providing and Fixing steel windows 18 gauge with openable glazed panels With 22 SWG wire gauze: Glass pane 3mm

Cleaning of water tanks per gallon capacity

Providing and Fixing barbed wire fencing with 4 horizontal & 2 cross wires: With PCC 1:4:8 base 12"x12"x21"

P

Supplying and Fixing Polyethylene Water Tank made from food grade FDA Certified raw material, 3 layers UV stablized, inert with water, anti-fungus and anti-bacterial and have a service life of more than 10 years: 200 gallons (Horizontal)

E

Preparing surface & painting with snowcem/weathershield paint: First coat

Preparing surface & painting with snowcem / weathershield paint: 2nd & subsequent coats

Collection and submission at approved water testing laboratory of two water samples in bottles from each bore hole for testing.

P

Replacement of existing/ GM Peet valve including cost of Union, Nipple, Sockets etc: 1.5" dia

Replacement of existing/ GM Peet valve including cost of Union, Nipple, Sockets etc: 2" dia

Replacement of existing damaged rusted & chocked G.I pipe with new GI pipes of EN 10255-2004 (Medium Approved Quality) including laying, cutting, jointing, testing and disinfecting with socket joint including specials and valves etc.Complete as per specifications 1½" (40 mm) Nominal Pipe Size (NPS)

21

27-01

Repair of leakages in valve of already laid pipe line in trenches building i/c cost of extractiion/exvacation, complete in all respect of the following sizes. a) 3" to 6" dia of Valve

Each

25

672.42

16811

22

27-03

Removing of existing damaged rusted & chocked G.I pipe from 1/2" to 4" Nominal Pipe Size (NPS)

M

25

42.01

1050

Repair of C.I sluice valve/ reflux valve i/c packing sheet, mits, bolts, spindle etc: complete of the following size. a) 3" (75 mm) dia of Valve

23

24-51-a

Each

10

1,176.53

11765

24

Repair of C.I sluice valve/ reflux valve i/c packing sheet, nuts, bolts, spindle etc: complete of the following size.a) 4" (100 mm) dia of Valve

24-51-b

Each

5

1,372.61

6863

25

Repair of C.I sluice valve/ reflux valve i/c packing sheet, muts, bolts, spindle etc: complete of the following size. a) 6" (150 mm) dia of Valve

24-51-c

Each

8

1,568.70

12550

26

24-52-0

Repair /removal & testing of leakages in existing/-already laid pipe line i/c cost of extraction/ excavation with welding joint coating with bictumen/ red oxide and reinstallation to its original position after refilling with execavated material etc: complete in all respect of the following sizes. a) 6" (150 mm) dia of Valve

Each

15

2,470.38

37056

27

24-52-b

Repair /removal & testing of leakages in existing/ already laid pipe line i/c cost of extraction/ excavation with welding joint coating with bictumen/ red oxide and reinstallation to its original position after refilling with execavated material etc: complete in all respect of the following sizes. a) 4" (100 mm) dia of Valve

Each

23

2,382.90

54807

Repair /removal & testing of leakages in existing/ already laid pipe line i/c cost of extraction/ excavation with welding joint coating with bictumen/ red oxide and reinstallation to its original position after refilling with execavated material etc: complete in all respect of the following sizes. a) 3" (75 mm) dia of Valve

28

24-52-c

Each 20

2,071.65

41433

29

24-52-d

Repair /removal & testing of leakages in existing/already laid pipe line i/c cost of extraction/excavation with welding joint coating with bictumen/ red oxide and reinstallation to its original position after refilling with execavated material etc: complete in all respect of the following sizes. a) 2" (50 mm) dia of Valve

Each

20 1,984.16

39683

30

24-22-0-1

Providing and Fixing of Sluice valve of BSSquality (BS 5163) for GI, PVC, MS, HDPE andalso for all type of pipes i/c rubber sheet, jointing material complete in all respect PN-16, 3" (75 mm) dia of Valve

Each

1

37,365.09

37365

Providing and Fixing of Sluice valve of BSSquality (BS 5163) for GI, PVC, MS, HDPE andalso for all type of pipes i/c rubber sheet, jointing material complete in all respect PN-16, 4" (100 mm) dia of Valve

31 24-22-b-01

Each

1

48,489.03

48489

32

24-72-b

Providing and fixing G.I Flanges4" dia (5/8"Thick)

Pair

6

33

24-72-c

Providing and fixing G.1 Flanges 6" dia (5/8"Thick)

Pair

6

750.83

1,073.70

4505

6442

34

24-72-a

Providing and fixing G.1 Flanges 3" dia (5/8"Thick)

Providing, laying, cutting, jointing, testing and disinfecting GI pipeline in trenches, with socket joint, using GI pipes of EN 10255-2004 (Approved Light quality) including specials etc. Complete as per specifications 3" Nominal Pipe Size (NPS)

Providing, laving, cutting, jointing, testing and disinfecting GI pipeline in trenches, with socket joint, using GI pipes of EN 10255-2004 (Approved Light quality) including specials etc. Complete as per specifications "2" Nominal Pipe Size (NPS)

10255-2004 (Approved Light quality) including specials etc. Complete as per specifications except excavation. "1%" Nominal Pipe Size (NPS)

Providing, laying, cutting, jointing, testing and disinfecting GI pipeline in trenches, with socket joint, using GI pipes of EN 10255-2004 (Approved Light quality) including specials etc. Complete as per specifications except excavation. 1" Nominal Pipe Size (NPS)

Providing and Fixing Brass peet/gate valve 2" dia

Cement pointing struck joints, on walls, upto 20' height: Ratio 1:3

Supplying and Fixing 18 SWG MS Sheet Door with angle iron frame (1.5"x1.5"x1/8"), bolt, hinges, paint etc complete

White washing: Old surface: Two coats

White washing: New surface: Three coats

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation (250 mm dia) PN-16

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation (110 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation. (90 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation. (75 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation (63 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation (50 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/ISO-4427 in trenches, complete in all respects except excavation (40 mm dia) PN-10

Providing, laying, cutting, jointing, testing and disinfecting High Density Polyethylene Pipe (HDPE) Din-8074/Din-8075/1SO-4427 in trenches, complete in all respects except excavation. (32 mm dia) PN-10

Providing and installing HDPE adaptor 110mm

Providing and installing HDPE adaptor 90mm

Providing and installing HDPE adaptor 75mm

Providing and installing HDPE adaptor 63mm

Providing and installing HDPE adaptor 50mm

Providing and installing HDPE adaptor 40mm

Providing and installing HDPE adaptor 90mm

Providing and installing HDPE adaptor 75mm

Providing and installing HDPE adaptor 63mm

Providing and installing HDPE adaptor 50mm

Providing and installing HDPE adaptor 40mm

Providing and installing HDPE adaptor 32mm

Providing and installing HDPE Socket 110mm dia

Providing and installing HDPE Socket 90mm dia

Providing and installing HDPE Socket 75mm dia

Providing and installing HDPE Socket 63mm dia

Providing and installing HDPE Socket 50mm dia

Providing and installing HDPE Socket 40mm dia

Providing and installing HDPE Socket 32mm dia

Providing and installing HDPE Tee 110mm dia

Providing and installing HDPE Tee 90mm dia

Providing and installing HDPE Tee 75mm dia

Providing and installing HDPE Tee 63mm dia

Providing and installing HDPE Tee 50mm dia

Providing and installing HDPE Tee 40mm dia

Providing and installing HDPE Tee 32mm dia

Providing and installing HDPE bend 110mm dia

Providing and installing HDPE bend 90mm dia

Providing and installing HDPE bend 50mm dia

Providing and installing HDPE bend 40mm dia

Providing and installing HDPE bend 32mm dia

Cleaning and washing of tubewell with air compressor in all sizes and depth, 8" i/d and above

Testing and developing of tubewell with DNT unit 8" i/d and above complete as per specifications

Test & develope tubewell of size 6" & above continously up to 1.5 cuse cs (Air compressor)

Excavation of trench in all kinds of soils except cutting in rock for pilelines upto 1.5m depth

Removal of leakages/Jointing of Existing laid Pipeline with butt fusion welding joint including cost of extraction of damaged section of pipe, dewatering of leaked water from damage section, and re-installation to its orignal position after backfilling with excavated material etc complete in all respect. (250 mm PN-16)

Removal of leakages/Jointing of Existing laid Pipeline with butt fusion welding joint including cost of extraction of damaged section of pipe, dewatering of leaked water from damage section, and re-installation to its orignal position after

Testing of water sample chemically copmlete in all respect

Testing of water sample microbally copmlete in all respect

Water quality test Biological/Chemical/Physical parameter.

Relaying of Pipe Line in Trenches

Chlorination of tube well copmlete in all respect

S/Fixing of chlorine

House Hold Connection