| UNITED NATION INTERNATIONAL ORGANIZATION FOR MIGRATION UN-IOM |
|||||
| Building 2 (Maintenance Works) | |||||
| Bill of Quantities (Measurments Sheet) | |||||
| Item.No | Description of work | Quantity | Unit | Unit Rate (PKR) |
Amount (PKR) |
| Reception | |||||
| 1 | Flush drain repair (unclog/replace trap, seal). All work as per Engineer’s approval; debris removed within 15m lead. | 2 | Jobs | ||
| 2 | Flush leak repair (cistern/flush kit) – with Sonex/Pak PVC flush system or equivalent approved brand. | 10 | Jobs | ||
| 3 | Muslim shower replacement (hand bidet set incl. stopcock & hose – Sonex/Popular/approved by Engineer). Complete in all respect. | 14 | Nos. | ||
| 4 | Washroom ceiling leakage – identify & fix (using Sika/Fosroc sealants & cementitious waterproofing). Debris removed within 15m lead. Complete in all respect and as approved by the Engineer in charge. | 1 | Job | ||
| 5 | Commode seat replacement – Porta/Marachi/Marachi Premium Brand seat cover. | 1 | No. | ||
| 6 | Kitchen leakage – identify the problem & rectify (Sika/Fosroc chemical injection or approved method). Debris removed within 15m lead as per Engineer In charge. Complete in all respect. | 2 | Points | ||
| 7 | Commode base leaking – reseat with sealant/grout (Sika Grout 214 / Fosroc Conbextra GP). | 4 | Nos. | ||
| 8 | Sink drain pipe broken – replace trap/pipe (Dadex/Popular PVC traps). | 2 | Nos. | ||
| 9 | Cabinet flush door broken – carpentry repair only fixing hardware (approved by Engineer). | 2 | No. | ||
| 10 | Wall leakage due to AC drain – reroute/repair drain with Dadex PVC pipes. | 6 | Points | ||
| 11 | Windows leakage – Sealant/closure issues (Provisional Sum – ICI/Berger Weatherseal + Dow Corning sealant). | 1 | Job | ||
| 12 | AC cassette water leakage to smoke detector – Defect identification and resolution waterproofing/drain cleaning/float adjustment depending on site and as per Engineer In charge. | 1 | Job | ||
| 13 | AC leakage (split) – drain/flare check identification/resolution as per Engineer in charge. | 1 | Job. | ||
| 14 | Room wall leaking – Defect Identification, Resolution, skirting & waterproofing (Provisional, ICI Dulux DampSeal / Sika waterproofing). Complete in all respect as per Engineer in charge. | 1 | Room | ||
| 15 | Commode broken – supply & install new WC set (Porta/Marachi Standard, with PVC flushing system) complete. | 2 | No. | ||
| 16 | AC drain pipes leak (concealed) – repair (Dadex PVC, refinish plaster with ICI Paints). Debris removed within 15m lead and as per Engineer in charge complete in all respect. | 5 | Point | ||
| 17 | Drain pipe leakage in ceiling – repair (Dadex PVC + sealant). Debris removed within 15m lead. | 1 | Point | ||
| 18 | Rodent ingress via duct – investigation & sealing (Provisional, with MS grating). | 1 | Job | ||
| 19 | Washroom wall leakage – identify & resolve (Sika/Fosroc method). Complete in all respect as approved by Engineer in Charge. | 1 | Job | ||
| 20 | Sliding door glass panel/frame fix with 2 and1/2 inch wooden frame to support the frame 12ft long. Complete fix and as approved by Engineer in charge. | 1 | No. | ||
| 21 | Crack in room ceiling – repair & refix the ceiling and replace with matching one if broken.2 (2'x2') ceiling panel. Crack should be grouted first, then filled with cementicious admixture seal and water proofed as per the instruction of Engineer in charge. | 1 | Point | ||
| 22 | Leakage on walls in rooms – identify the cause & resolve (ICI/Berger Damp-proof + Sika chemical injection) as per Engineer in charge, debris dump upto 15m. Check if skirting is needed. Fix complete in all respect. | 5 | Wall | ||
| 23 | Windows leaking – waterproofing & sealing (Provisional, Dow Corning + Weatherseal). | 2 | Jobs | ||
| 24 | Emergency exit water ingress – waterproof & create slope (Brushbond / PCC screed). Fix the problem. And approved it from Engineer. | 1 | Job | ||
| 25 | Water leaking from ceiling – repair points (PU injection + re-plaster). Debris removed within 15m lead. Complete in all respects and as per the Engineer in charge. | 2 | Points | ||
| 26 | Paint Work Matching Distemper, scapping and wall putty lum sum. |
250 | Sft | ||
| 27 | 6" Exhaust Fan – 220–240V, 15–30W copper motor, ~250–300 CFM airflow, wall/window mount, approved brands: Royal, or as per Engineer’s approval | 3 | Nos. | ||
| 28 | Sealent for glass partition to fix its Vibration | 1 | Job | ||
| 29 | Wall Panell matching with site. | 400 | sft | ||
| 30 | AC cassette is leaking. Root cause analysis and fix. Complete in all respect as approved by Engineer. | 1 | Job | ||
| Maintenance Works Total | |||||
| 31 | Windows leakage – no shade (Provisional, fabrication in fiber shade along with supports/anchor with paint). 44 windows , shade 3' wide, length according to window, curved and extended from side. Good Quality and approved by the Engineer in charge. Shuttering, transportation and labour included. Complete in all respect. | 350 | RFT | ||
| Fiber Shades for Windows | |||||